Hot
-44%

GEYA – Residual Current Device กันดูด RCD TYPE B (1P+N 30mA)

Original price was: 7,000.00 ฿.Current price is: 3,900.00 ฿.

Reviews Summary by AI:

กันดูด RCD Type B GEYA รุ่น เหมาะกับงานติดตั้ง EV Charger, Wallbox
ตัดกระแสรั่วที่ 30mA ใช้กับไฟ 1 เฟส 40A

  • ขนาด 40A
  • ยี่ห้อ GEYA
  • 1 เฟส 1P+N (2 Pole/2 สาย)
  • ตัดกระแสรั่วที่ 30mA
  • มาตรฐานยุโรป CE IEC / EN 62423 & IEC / EN 61008-1

Single Phase Residual Current Device RCD TYPE B EV use
Rated current: 40A
mA rating: 30mA
Voltage: 220 ~ 240 VAC 50/60Hz
Short-circuit breaking capability: 10kA IEC / EN 62423 & IEC / EN 61008-1
CE-marked: Yes
Number of poles: 2P (1 Phase+ Neutral)
Type Description: B-Class (Type B): Standard protection
Fits (among others) Tesla Powerwall
Fault current indicator: Yes
IP rating: IP20
Dimensions: 72mmx77mmx85mm (Din 4 module widths)

Availability: มีสินค้า รหัสสินค้า: 654111995-1-1-2-2-1-1-1-1

คำอธิบาย

GEYA GYL9 – Residual Current Device RCD TYPE B (1P+N 30mA)

Description

RCD Type B Description:
Single Phase GEYA 40A DC earth leakage 30mA, Type B 10KA RCD for EV use (for e-mobility)
(2 Pole Variants available)
Ground fault switch for charging station for electric cars, electric hybrids, charging hybrids. The ground fault circuit breaker of TYPE B has since 2017 been a requirement for charging electric cars. We offer the right switch for a difficult price. Fits (among others) Tesla Powerwall. That is China Best Manfaucturer’s products.
In the case of electric car charging and solar installations, you must have an earth fault breaker type B according to the new electrical installation rules 2017 (Edition 3 of SS 436 40 00). It is a Swedish standard that should be followed. The reason for this is that an ordinary earth leakage circuit breaker can stop working if it is used in these contexts, which in the worst case can lead to fire or electric accidents.
Type B RCDs provide protection against DC Residual Fault Currents.
Type B RCDs are used where DC residual currents can occur, for example, Electric Vehicle Charging, three phase rectified supplies, micro generation or SSEGs (Small Scale Electricity Generators) such as solar panels and wind generators.
Function:
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
Safe use
A suitable rated RCBO/RCD device may also be required in the final circuit to provide the correct level of protection whilst avoiding unnecessary tripping. Always consult wiring regulations or a electrical contractor to be sure.
General information:
Rated current: 40A
Voltage: 220 ~ 240 VAC
Short-circuit breaking capability: 10kA IEC / EN 62423 & IEC / EN 61008-1
CE-marked: Yes
Number of poles: 2P
Class: B
IΔm: 500A
Protection class: IP20
Mechanical life: 2000 connections
Electrical life: 2000 connections
Operating temperature: -25… + 40˚C with an ambient temperature of 35˚C
Type Description: B-Class (Type B): Standard protection
Fits (among others) Tesla Powerwall.
Standard: IEC/EN 61009-1, IEC/EN 62423

size chest(in.) waist(in.) hips(in.)
XS 34-36 27-29 34.5-36.5
S 36-38 29-31 36.5-38.5
M 38-40 31-33 38.5-40.5
L 40-42 33-36 40.5-43.5
XL 42-45 36-40 43.5-47.5
XXL 45-48 40-44 47.5-51.5

ข้อมูลเพิ่มเติม

น้ำหนัก 23 กก.
ขนาด 12 × 23 × 56 เซนติเมตร
Brand

GEYA

Color

Green, Indigo

รีวิว

ยังไม่มีบทวิจารณ์


เฉพาะลูกค้าที่เข้าสู่ระบบ และเคยซื้อสินค้าชิ้นนี้แล้วเท่านั้น ที่เขียนบทวิจารณ์ได้

คุณอาจจะชื่นชอบ…